TECHNIC 10000 E Generating set

TECHNIC 10000 E Portable Power Generating set, equipped with KOHLER engine.


Direct access to sections

GENERAL SPECIFICATIONS

Range TECHNIC
Frequency (Hz) 50 Hz
Max power LTP (kW) 10.50
Nominal voltage (V) 230
Number of Phase Single phase
Fuel Petrol
Tank (L) 33
75% cons. (l/h) 5
75% Autonomy (h) 6.60
Sound power level guaranteed LwA dB(A) 97
Acoustic pressure level @1m in dB(A) 83
Acoustic pressure level @7m in dB(A) 69

ENGINE SPECIFICATIONS

Engine brand KOHLER
Engine ref. CH680
Distribution O.H.V.
Start Electrical
Oil shutdown Oui
Displacement (cm3) 674
Oil system capacity including filters (L) 1.90

ALTERNATOR SPECIFICATIONS

Technology Brushless
AVR Regulation No
Indication of protection IP 23
Insulation class H

PLUGS AND PANEL DESCRIPTIVE

1 230V 10/16A socket - circuit breaker + 1 230V 16A socket - circuit breaker + 1 230V 32A socket - circuit breaker + hour meter + indicator + APM202

DIMENSIONS AND WEIGHT

Lenght (cm) 89.50
Width (cm) 57
Height (cm) 77
Dry Weight (kg) 167

PACKAGING

Packaging type Box / Pallet
Length (cm) 91
Width (cm) 58.50
Height (cm) 92
Weight (kg) 180
Number of box by pallet 0
Pallet height (cm) 0
weight of the packaged Pallet (kg) 0

PRODUCT ADVANTAGES

Entire group guaranteed 3 years
KOHLER air-cooled industrial engine
Electric starter with batteries without maintenance
Large Autonomy
Connection interface equipped with an hour meter and the APM202 control unit

ACCESSORIES SUPPLIED

Funnel
User and maintenance manual
Battery without maintenance
Hour meter

OPTIONS

R02B R02B
This set includes a differential switch, a hour meter, the plugs and a thermal circuit breaker.

3499231002834 RSTART2
Remote control in order to start or stop the generating set until a distance of 50 meters (needs the APM202 control panel)

3499231001110 VERSO50
Switches over automatically if the mains fails, 40A or 100A 1P or if the mains fails, 25A or 40A 3P (needs the installation of a APM202 control panel). Includes the battery charger.

R05M R05M
The manual changeover switch is used to connect and disconnect a generating set manually to a domestic circuit when there is a power cut.

RKB2 RKB2
Trolley kit for the generating sets superior to 6kW

3499231920060 RKS5
Maintenance kit for KOHLER CH680 engine.

RAP Adaptor for industrial sockets
ERR:not found in dict valeurs

RH2 RH2
Cover for SDMO 's generating sets, welding sets and water pumps

RPM RPM
Male plugs for all models made up of : 2 x 16 A/230 V, EEC17: 1 x 16A/230 V, 1 x 32A/230 V and 1 x 16A/400V

RPQ RPQ
For earthing your generator set. Galvanised 1 m long spike, supplied with 2 m of 10 mm² cable.

Réalisation : id3i.fr