Engine type
|
4045TF120
|
|
Alternator type
|
LSA432M45-SH-F12
|
|
Performance class
|
G3
|
|
Frequency (Hz)
|
50
|
|
Reference voltage (V)
|
400/230
|
|
Max power ESP (kVA)
|
66
|
|
Max power ESP (kWe)
|
52.80
|
|
Max power PRP (kVA)
|
60
|
|
Max power PRP (kWe)
|
48
|
|
Intensity (A)
|
95
|
|
Standard Control Panel
|
NEXYS
|
|
Optional control panel
|
TELYS
|
|
Optional Control Panel
|
N/A
|
|
Optional control panel
|
N/A
|
|
Mechanic governor
|
|
Mechanically welded chassis with antivibration suspension
|
|
Main line circuit breaker
|
|
Radiator for wiring temperature of 48/50°C max with mechanical fan
|
|
Protective grille for fan and rotating parts
|
|
9 dB(A) silencer supplied separately
|
|
Charger DC starting battery with electrolyte
|
|
12 V charge alternator and starter
|
|
Delivered with oil and coolant -30°C
|
|
Manual for use and installation
|
|
Voltages
|
ESP
|
PRP
|
Back-up power
|
|
kWe
|
kVA
|
kWe
|
kVA
|
|
415/240
|
53
|
66
|
48
|
60
|
92
|
|
400/230
|
53
|
66
|
48
|
60
|
95
|
|
380/220
|
53
|
66
|
48
|
60
|
100
|
|
200/115
|
53
|
66
|
48
|
60
|
191
|
|
240 TRI
|
53
|
66
|
48
|
60
|
159
|
|
230 TRI
|
53
|
66
|
48
|
60
|
166
|
|
220 TRI
|
53
|
66
|
48
|
60
|
173
|
|
220/127
|
53
|
66
|
48
|
60
|
173
|
|
Engine model
|
JOHN DEERE
|
|
Engine type
|
4045TF120
|
|
Air inlet
|
Turbo
|
|
Air coolant
|
N/A
|
|
Number of cylinders
|
4
|
|
Cylinder arrangement
|
L
|
|
Displacement (C.I.)
|
4.48
|
|
Bore (mm)
|
106
|
|
Stroke (mm)
|
127
|
|
Compression ratio
|
17 : 1
|
|
Speed (RPM)
|
1500
|
|
Pistons speed (m/s)
|
6.35
|
|
Maximum stand-by power at rated RPM (kW)
|
70
|
|
Frequency regulation (%)
|
+/- 2.5%
|
|
BMEP (bar)
|
11.24
|
|
Governor type
|
Mechanical
|
|
Exhaust gas temperature (°C)
|
545
|
|
Exhaust gas flow (L/s)
|
176
|
|
Max. exhaust back pressure (mm EC)
|
750
|
|
Consumption @ 110% load (L/h)
|
17.50
|
|
Consumption @ 100% load (L/h)
|
16
|
|
Consumption @ 75% load (L/h)
|
12
|
|
Consumption @ 50% load (L/h)
|
8.50
|
|
Maximum fuel pump flow (L/h)
|
108
|
|
Oil capacity (L)
|
13.50
|
|
Min. oil pressure (bar)
|
1
|
|
Max. oil pressure (bar)
|
5
|
|
Oil consumption 100% load (L/h)
|
0.016
|
|
Carter oil capacity (L)
|
12.50
|
|
Heat rejection to exhaust (kW)
|
54
|
|
Radiated heat to ambiant (kW)
|
8
|
|
Haet rejection to coolant (kW)
|
35
|
|
Max. intake restriction (mm EC)
|
625
|
|
Intake air flow (L/s)
|
66
|
|
Radiator & Engine capacity (L)
|
23.60
|
|
Max water temperature (°C)
|
105
|
|
Outlet water temperature (°C)
|
93
|
|
Fan power (kW)
|
1.40
|
|
Fan air flow w/o restriction (m3/s)
|
2.53
|
|
Available restriction on air flow (mm EC)
|
20
|
|
Type of coolant
|
Gencool
|
|
Thermostat (°C)
|
82-94
|
|
Emission PM (mg/Nm3)
|
60
|
|
Emission CO (mg/Nm3)
|
190
|
|
Emission HCNOx (mg/Nm3)
|
N/A
|
|
Emission HC (mg/Nm3)
|
150
|
Alternator specifications
|
Alternator brand
|
LEROY SOMER
|
|
Alternator type
|
LSA 43.2 M45
|
|
Number of phase
|
3
|
|
Power factor (Cos Phi)
|
N/A
|
|
Altitude (m)
|
0 à 1000
|
|
Overspeed (rpm)
|
2250
|
|
Number of pole
|
4
|
|
Excitation system
|
SHUNT
|
|
Insulation class
|
H
|
|
T° class, continuous 40°C
|
H / 125°K
|
|
Regulation
|
N/A
|
|
Harmonic factor, no load TGH/THC (%)
|
<2
|
|
Wave form : NEMA=TIF-(TGH/THC)
|
<50
|
|
Wave form : CEI=FHT-(TGH/THC)
|
<2
|
|
Number of bearing
|
1
|
|
Coupling
|
Direct
|
|
Voltage regulation at established rating (%)
|
+/- 0.5%
|
|
Recovery time (Delta U = 20% transcient) (ms)
|
500 ms
|
|
Continuous Nominal Rating 40°C (kVA)
|
60
|
|
Standby Rating 27°C (kVA)
|
66
|
|
Efficiencies 4/4 load (%)
|
89
|
|
Air flow (m3/s)
|
0.27
|
|
Short circuit ratio (Kcc)
|
0.39
|
|
Direct axis synchro reactance unsaturated (Xd) (%)
|
304
|
|
Quadra axis synchro reactance unsaturated (Xq) (%)
|
182
|
|
Open circuit time constant (T'do) (ms)
|
1270
|
|
Direct axis transcient reactance saturated (X'd) (%)
|
11.90
|
|
Short circuit transcient time constant (T'd) (ms)
|
50
|
|
Quadra axis subtranscient reactance saturated (X"q) (%)
|
7.40
|
|
Subtranscient time constant (T"d) (ms)
|
5
|
|
Quadra axis subtranscient reactance saturated (X"q) (%)
|
7.40
|
|
Zero sequence reactance unsaturated (Xo) (%)
|
0.50
|
|
Negative sequence reactance saturated (X2) (%)
|
6.70
|
|
Armature time constant (Ta) (ms)
|
8
|
|
No load excitation current (io) (A)
|
0.40
|
|
Full load excitation current (ic) (A)
|
1.60
|
|
Full load excitation voltage (uc) (V)
|
30
|
|
Recovery time (Delta U = 20% transcient) (ms)
|
500 ms
|
|
Engine start (Delta U = 20% perm. or 50% trans.) (kVA)
|
156
|
|
Transcient dip (4/4 load) - PF : 0,8 AR (%)
|
15.50
|
|
No load losses (W)
|
1120
|
|
Heat rejection (W)
|
5890
|
|
Length (mm)
|
1870
|
|
Width (mm)
|
994
|
|
Height (mm)
|
1360
|
|
Dry weight (kg)
|
1000
|
|
Tank capacity (L)
|
180
|
|
Canopy
|
M128
|
|
Length (mm).
|
2300
|
|
Width (mm).
|
1060
|
|
Height (mm).
|
1680
|
|
Dry weight (kg).
|
1410
|
|
Tank capacity (L).
|
180
|
|
Acoustic pressure level @1m in dB(A) (N/A)
|
75 (0.47)
|
|
Sound power level guaranteed (Lwa)
|
92
|
|
Canopy
|
M128 DW
|
|
Length (mm).
|
2344
|
|
Width (mm).
|
1060
|
|
Height (mm).
|
1900
|
|
Dry weight (kg).
|
1657
|
|
Tank capacity (L).
|
390
|
|
Acoustic pressure level @1m in dB(A) (N/A)
|
74 (0.47)
|
|
Sound power level guaranteed (Lwa)
|
92
|
|
Canopy
|
M128 DW48
|
|
Length (mm).
|
2344
|
|
Width (mm).
|
1060
|
|
Height (mm).
|
1989
|
|
Dry weight (kg).
|
1687
|
|
Tank capacity (L).
|
700
|
|
Acoustic pressure level @1m in dB(A) (N/A)
|
74 (0.47)
|
|
Sound power level guaranteed (Lwa)
|
92
|
The NEXYS is a versatile control unit allowing operation in manual or automatic mode. Equipped with an LCD screen, the user-friendly NEXYS offers high-quality basic functions to guarantee simple, reliable operation of your generating set.
Offers the following functions:
Standard electrical measurements: voltmeter, frequency meter, ammeter.
Engine parameters: working hours counter, engine speed, battery voltage, fuel level.
Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed (> 60 kVA), charging alternator fault, low fuel level, emergency stop.
For more information, please refer to the sales documentation.
The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication.
The TELYS offers the following functions:
Electrical measurements: voltmeter, frequency meter, ammeter.
Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage.
Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level.
Ergonomics: wheel for navigating around the various menus.
Communication: remote control and operation software, USB connections, PC connection.
For more information on the product and its options, please refer to the sales documentation.